Drop-Type Fuses · 35 kV · Silicone polymer
The RW12-35 is a 35 kV expulsion drop-out fuse cutout for 33 kV and 35 kV overhead distribution lines. It protects pole-mounted transformers, capacitor banks and line sections against overload and short-circuit current by melting a replaceable fuse link and then dropping the carriage clear, so the fault is visible from the ground and the open point is isolated without a switching operation.
This version carries a silicone polymer insulator. Polymer sheds are lighter than porcelain, do not shatter on impact and keep their surface hydrophobic in coastal and heavily polluted service, which is why most 33 kV line projects in the Gulf and West Africa now specify them. The fuse tube is UV-stabilised with an internal arc-quenching liner, and all current-carrying contacts are silver-plated copper.
Price
On request
MOQ 1 piece
Typical applications for the 35 kV class cutout.
Manufacturer data for the 35 kV Silicone polymer version.
| Parameter | 100 A version | 200 A version |
|---|---|---|
| Rated voltage | 35 kV | 35 kV |
| Rated current / base rated current | 100 A | 200 A |
| Rated frequency | 50 Hz | 50 Hz |
| Rated short-circuit breaking current (kA / A) | 12.5/100 · 16/100 | 12.5/200 · 16/200 |
| Power-frequency withstand, wet | 95 kV | 95 kV |
| Power-frequency withstand, dry | 95 kV | 95 kV |
| Rated lightning impulse voltage | 200 kV | 200 kV |
| Creepage distance | 1,256 mm | 1,256 mm |
| Mechanical endurance | 500 operations | 500 operations |
| Altitude | 1,000 m | 1,000 m |
| Ambient temperature | -10 ... +70 °C | -10 ... +70 °C |
| Overall dimensions | 90 x 40 x 17 cm | 90 x 40 x 17 cm |
Values as published in the manufacturer parameter table. Breaking ratings are quoted for the 100 A and 200 A fuse links respectively.

Dimensions on the drawing: 640 mm and 675 mm heights, 380 mm mounting pitch, 35 mm terminal offset. Check the drawing against your cross-arm before ordering.
Three numbers decide whether a 35 kV cutout is right for a line: the system voltage (33 or 35 kV), the transformer rating that sets the fuse-link current, and the creepage the site needs. The published creepage figure for the silicone polymer version is 1,256 mm, about 36 mm/kV at 35 kV; whether that satisfies your project depends on the pollution level your specification quotes, so send us the required specific creepage and we will confirm the shed profile against the drawing before the order is released. If your specification quotes a 12(15) kV cutout, it is a different product — see the RW33-15 and RW12-15F pages for the 10–15 kV class.
No. RW12-35 is a 35 kV cutout for 33 kV and 35 kV lines. RW33-15, despite the 33 in its name, is rated 12(15) kV for 10-15 kV systems. Always check the rated voltage row of the datasheet before releasing an order.
Polymer. Silicone sheds stay hydrophobic after surface contamination, weigh about a third less than porcelain and fail without shattering. The impulse level is also higher on the polymer version (200 kV against 170 kV), which gives more margin on a 35 kV line.
Size the link to the transformer rating, not to the cutout: the link must carry the transformer full-load current and still clear a secondary fault. Cutouts are supplied without links unless the order states the rating, so tell us the transformer kVA and we will quote the matching link.
Yes, with a standard hot-stick on the pull ring - that is the point of the drop-out design. Do not operate it by hand, and do not re-close a cutout that has dropped until the fault has been located.